• DocumentCode
    1739175
  • Title

    ESD evaluation of tunneling magnetoresistive (TMR) devices

  • Author

    Wallash, Albert ; Hillman, James ; Wang, Dexin

  • Author_Institution
    Quantum Corp., Milpitas, CA, USA
  • fYear
    2000
  • fDate
    26-28 Sept. 2000
  • Firstpage
    470
  • Lastpage
    474
  • Abstract
    In this work, we study and compare the dielectric breakdown and human body model electrostatic discharge (ESD) failure levels of tunneling magnetoresistive (TMR) sensors. An equivalent circuit for the TMR device is developed and used in SPICE circuit simulations to study its response to electrostatic discharge. Dielectric breakdown averaged 2.3 V and ESD testing showed device shorting at 8.6 V HBM.
  • Keywords
    SPICE; circuit simulation; electric breakdown; electrostatic discharge; equivalent circuits; magnetic heads; magnetic recording; magnetic sensors; magnetoresistive devices; tunnelling; 2.3 V; 8.6 V; ESD evaluation; ESD testing; HBM; SPICE circuit simulation; TMR devices; TMR sensors; device shorting; dielectric breakdown; electrostatic discharge response; equivalent circuit; human body model ESD failure; human body model electrostatic discharge failure; tunneling magnetoresistive devices; tunneling magnetoresistive sensors; Biological system modeling; Circuit simulation; Circuit testing; Dielectric breakdown; Electrostatic discharge; Equivalent circuits; Humans; Magnetic sensors; SPICE; Tunneling magnetoresistance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/Electrostatic Discharge Symposium Proceedings 2000
  • Conference_Location
    Anaheim, CA, USA
  • Print_ISBN
    1-58537-018-5
  • Type

    conf

  • DOI
    10.1109/EOSESD.2000.890118
  • Filename
    890118