Sensation evoked by simultaneous electrical stimulation of two single mechanoreceptor units
Author :
Suzuki, Takafumi ; Kunimoto, Masaya ; Shimojo, Makoto ; Saito, Takashi ; Ishikawa, Masatoshi ; Mabuchi, Kunihiko
Author_Institution :
Center for Collaborative Res., Tokyo Univ., Japan
Volume :
2
fYear :
2000
fDate :
2000
Abstract :
Two tungsten microelectrodes were inserted percutaneously at two points on the forearm of awake human subjects into the median nerve and adjusted so that the activity of each single mechanoreceptor unit could be recorded. After identifying the types of units, the properties of the sensation evoked by simultaneous electrical stimulation were investigated by comparing them with those of the individual stimuli from the electrodes. To date, experiments have been done on the combination of two SAI units whose receptive fields did not overlap. For this combination, no “phantom sensation” was observed. The evoked sensation was the simple sum of those evoked by the individual stimuli. We are now experimenting with other combinations of units
Keywords :
bioelectric phenomena; biomedical electrodes; mechanoception; microelectrodes; neurophysiology; W; activity; awake human subjects; evoked sensation; forearm; individual stimuli; median nerve; phantom sensation; receptive fields; simultaneous electrical stimulation; tungsten microelectrodes; two SAI units; two single mechanoreceptor units; Artificial limbs; Electrical stimulation; Electrodes; Humans; Imaging phantoms; Microelectrodes; Pressure control; Shape; Skin; Tungsten;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE