A single, well-chosen electron beam, suitably modulated by additional photon beams, can deliver a homogeneous dose to the target while reducing the integral dose to normal tissue. This work compares plans using 21 MeV electrons mixed with modulated photons, with 6 MV intensity modulated photons alone in several configurations. The mixed beam plan achieved a 2-fold reduction in integral dose with little compromise in target homogeneity
Keywords
X-ray applications; dosimetry; electron beam applications; radiation therapy; 21 MeV; 6 MV; additional photon beams; beam modulation; integral dose reduction; intensity modulated photon beams; mixed electron-photon radiotherapy; normal tissue; radiotherapy dosimetry; single well-chosen electron beam; target homogeneity; Biological system modeling; Biomedical applications of radiation; Electromagnetic scattering; Electron beams; Fluctuations; Intensity modulation; Oncology; Optical modulation; Particle scattering; Protons;