Multileaf collimation for electron intensity modulation
Author :
Kudchadker, R.J. ; Hogstrom, K.R. ; Boyd, R.A.
Author_Institution :
Dept. of Radiat. Phys., Texas Univ., Houston, TX, USA
Volume :
1
fYear :
2000
fDate :
2000
Firstpage :
210
Abstract :
Dynamic multileaf collimation (DMLC) could prove useful in electron conformal therapy, arc electron therapy, and electron field abutment. For these applications, it is first necessary to understand the ability of the DMLC to modulate electron fluence and its effect on the resulting dose distribution. The objectives of this work were to demonstrate the ability of the pencil-beam algorithm to fit the electron dose distribution created by the DMLC and to demonstrate for non-normal incidence on a flat phantom that the DMLC can restore dose uniformity. Measurements were performed using 12 and 20 MeV electrons with the 25×25 cm2 applicator. Dose was measured using film placed at a depth of 2 cm in a plastic phantom at 100 cm SSD. First, measurements were made with the MLC set to 10×10 cm2 and 20×20 cm2. Another irradiation simulated modulation by irradiating with square fields followed by the MLC blocking half the field. These results showed that the pencil beam algorithm can accurately predict the off-axis dose profiles. Second, the beam was angled at 30° from the normal incidence creating a gradient in dose uniformity. Then, the beam was modulated to achieve dose uniformity by gradually closing the leaves from the side closest to the phantom to the side furthest away. These results indicated that the DMLC can restore beam uniformity for cases where there is a low dose gradient
Keywords :
dosimetry; electron beam applications; intensity modulation; radiation therapy; 100 cm; 2 cm; 20 MeV; arc electron therapy; dose uniformity restoration; electron conformal therapy; electron field abutment; electron intensity modulation; flat phantom; multileaf collimation; nonnormal incidence; off-axis dose profiles prediction; pencil beam algorithm; plastic phantom; Applicators; Collimators; Electrons; Imaging phantoms; Intensity modulation; Medical treatment; Optical modulation; Performance evaluation; Plastic films; Prediction algorithms;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
ISSN :
1094-687X
Print_ISBN :
0-7803-6465-1
Type :
conf
DOI :
10.1109/IEMBS.2000.900708
Filename :
900708
Link To Document :
بازگشت