• DocumentCode
    1741442
  • Title

    Electrical interactions between cardiac cells studied with coupling clamp and model clamp

  • Author

    Wilders, Ronald ; Verheijck, Etienne ; Wagner, Mary B. ; Joyner, Ronald W. ; Jongsma, Habo J.

  • Author_Institution
    Univ. Med. Centre Utrecht, Utrecht Univ., Netherlands
  • Volume
    1
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    653
  • Abstract
    In the early nineties, Joyner et al. introduced the “coupling clamp” technique in which an isolated cardiac cell can be electrically coupled to either another isolated cardiac cell or to an analog model cell (RC circuit). In brief, an amplifier system does a continuous analog computation of the current that would be flowing between the two cells if there had been an intercellular coupling conductance Gc, and then provides current inputs to the cells accordingly. Building on this concept, the authors developed a computer-controlled coupling clamp system, as well as a “model clamp” system, in which an isolated cardiac cell is dynamically coupled in real time to a comprehensive mathematical cell model (e.g., the phase-2 Luo-Rudy model). With this system the authors have the ability to vary coupling conductance, effective size of both model cell and real cell, and intrinsic cellular properties of the model cell. The authors used the digital coupling clamp to study the synchronization of two sinoatrial nodal cells, and found that the critical value of coupling conductance required for 1:1 frequency entrainment was <0.5 nS, whereas Gc⩾10 nS was required for waveform entrainment. The authors used the model clamp to assess alterations in the critical value of coupling conductance required for action potential conduction from a real ventricular cell to the Luo-Rudy model ventricular cell when the real cell was exposed to a solution mimicking acute ischemia. They observed that conduction was inhibited in the standard `ischemic´ solution, but facilitated when noradrenaline was added to the `ischemic´ solution
  • Keywords
    bioelectric phenomena; cardiology; cellular biophysics; physiological models; 0.5 nS; 10 nS; RC circuit; amplifier system; analog model cell; cardiac electrophysiology; computer-controlled coupling clamp system; coupling clamp; electrical interactions between cardiac cells; isolated cardiac cell; model clamp; phase-2 Luo-Rudy model; sinoatrial nodal cells; Analog computers; Clamps; Coupling circuits; Frequency synchronization; Heart; Ischemic pain; Mathematical model; Multidimensional systems; Rabbits; Real time systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-6465-1
  • Type

    conf

  • DOI
    10.1109/IEMBS.2000.900829
  • Filename
    900829