DocumentCode :
174444
Title :
Passive common mode filter for reducing shaft voltage, ground current, bearing current in dual two level inverter fed open end winding induction motor
Author :
Kalaiselvi, J. ; Srinivas, S.
Author_Institution :
Dept. of Electr. Eng., Indian Inst. of Technol. Madras, Chennai, India
fYear :
2014
fDate :
22-24 May 2014
Firstpage :
595
Lastpage :
600
Abstract :
Dual two level inverter with open end winding can work as three level inverter. Inverter fed drives suffer from common mode issues like shaft voltage, ground currents and bearing currents. Dual inverter fed open end winding induction motor also suffer from these problems. This paper proposes passive filter configuration for reducing shaft voltage, ground currents and bearing current problems in dual two level open end winding drive. Well known space vector PWM (SVPWM) technique is used to verify the effectiveness of this filter configuration. This paper also presents a motor model for shaft voltage of this drive. Motor model and filter topology is first verified through MATLAB simulation and validated by experimental results.
Keywords :
PWM invertors; induction motors; machine windings; passive filters; power filters; MATLAB simulation; SVPWM technique; bearing current; dual two level inverter; filter topology; ground current; open end winding induction motor; passive common mode filter; passive filter configuration; shaft voltage; space vector PWM technique; Capacitance; Induction motors; Inductors; Inverters; Mathematical model; Shafts; Windings;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Optimization of Electrical and Electronic Equipment (OPTIM), 2014 International Conference on
Conference_Location :
Bran
Type :
conf
DOI :
10.1109/OPTIM.2014.6850977
Filename :
6850977
Link To Document :
بازگشت