DocumentCode
1745453
Title
Self calibration method to determine acoustic wave velocity in highly loaded liquids
Author
Meulen, F. Varider ; Feuillard, G. ; Lesaffre, C. ; Matar, O.B. ; Lethiecq, M. ; Patat, F.
Author_Institution
LUSSI, Blois, France
Volume
1
fYear
2000
fDate
36800
Firstpage
709
Abstract
Acoustic wave velocity determinations performed through time of flight measurement, require a time reference to be defined. Here, a minimum phase method is proposed to obtain a self calibrating measurement. Experimental results on particule-loaded liquids are obtained and found to be in good agrement with previously published results and with those of a theoretical homogenisation model
Keywords
acoustic wave velocity measurement; calibration; acoustic wave velocity; homogenisation model; minimum phase method; particulate loaded liquid; self-calibration; time reference; time-of-flight measurement; Acoustic measurements; Acoustic scattering; Acoustic waves; Calibration; Frequency; Liquids; Petroleum; Phase measurement; Transfer functions; Velocity measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium, 2000 IEEE
Conference_Location
San Juan
ISSN
1051-0117
Print_ISBN
0-7803-6365-5
Type
conf
DOI
10.1109/ULTSYM.2000.922645
Filename
922645
Link To Document