DocumentCode
1745483
Title
RF detection for low frequency cMUTS and its comparison to traditional detection
Author
Ergun, A.S. ; Hansen, S.T. ; Khuri-Yakub, B.T.
Author_Institution
Edward L. Ginzton Lab., Stanford Univ., CA, USA
Volume
1
fYear
2000
fDate
36800
Firstpage
935
Abstract
Capacitive micromachined transducers have long been used as generators and detectors of ultrasound both in air and immersion applications. Typically, the frequency of operation has been in the MHz range. However, they can still be operated at very low frequencies, where their mechanical sensitivity is poor, but the frequency response is flat. In this paper we show that, together with the RF detection method that provides a very sensitive and broadband acoustic detection, it is possible to operate the cMUTs at very low frequencies, which covers the microphone and sonar applications
Keywords
acoustic receivers; capacitive sensors; micromachining; microphones; ultrasonic transducers; RF detection; broadband acoustic detection; capacitive micromachined transducers; frequency response; microphone; sonar; Acoustic applications; Acoustic signal detection; Detectors; Frequency response; Microphones; Radio frequency; Sonar applications; Sonar detection; Ultrasonic imaging; Ultrasonic transducers;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium, 2000 IEEE
Conference_Location
San Juan
ISSN
1051-0117
Print_ISBN
0-7803-6365-5
Type
conf
DOI
10.1109/ULTSYM.2000.922694
Filename
922694
Link To Document