• DocumentCode
    1747652
  • Title

    Including effects of cross-saturation and leakage path saturation together in the generalized model of three phase induction machine

  • Author

    Almarshoud, A.F. ; Abdel-Halim, M.A. ; Alolah, A.I.

  • Author_Institution
    Coll. of Technol., Riyadh, Saudi Arabia
  • Volume
    1
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    195
  • Abstract
    This paper presents a new method for including the cross-saturation effect and the leakage path saturation effect together in the generalized model of a three phase induction machine. Four different cases of operation are investigated at load and no load. The machine performance has been determined with the help of a novel abc-dq circuit model. The model possesses the advantages of both the dq and direct phase model
  • Keywords
    asynchronous machines; machine theory; magnetic leakage; abc-dq circuit model; cross-saturation; direct phase model; dq model; generalized model; leakage path saturation; load operation; no load operation; three phase induction machine; Couplings; Educational institutions; Inductance; Induction machines; Magnetic circuits; Magnetic flux; Magnetic separation; Saturation magnetization; Stators; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical and Computer Engineering, 2001. Canadian Conference on
  • Conference_Location
    Toronto, Ont.
  • ISSN
    0840-7789
  • Print_ISBN
    0-7803-6715-4
  • Type

    conf

  • DOI
    10.1109/CCECE.2001.933682
  • Filename