DocumentCode :
1750008
Title :
Design considerations for piezoelectric polymer ultrasound transducers
Author :
Brown, L.F.
Author_Institution :
Dept. of Electr. Eng., South Dakota State Univ., Brookings, SD, USA
Volume :
1
fYear :
2000
fDate :
2000
Firstpage :
265
Abstract :
The purpose of this paper is to present new insight into seven important considerations for the design of active piezoelectric polymer ultrasound transducers: piezoelectric polymer materials selection, transducer construction and packaging requirements, materials characterization and modeling, film thickness and active area design, electroding selection, backing material design and front protection/matching layer design. The use of polymer wear-protection/quarter-wave matching layers is also discussed. Theoretical derivations are reported for optimizing the active area of the piezoelectric polymer element for maximum power transfer at resonance
Keywords :
piezoelectric transducers; polymer films; ultrasonic transducers; active area; backing material; design; electroding selection; film thickness; front protection; packaging; piezoelectric polymer ultrasound transducer; quarter-wave matching layer; wear protection layer; Building materials; Packaging; Piezoelectric films; Piezoelectric materials; Piezoelectric transducers; Polymer films; Protection; Resonance; Ultrasonic imaging; Ultrasonic transducers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applications of Ferroelectrics, 2000. ISAF 2000. Proceedings of the 2000 12th IEEE International Symposium on
Conference_Location :
Honolulu, HI
ISSN :
1099-4734
Print_ISBN :
0-7803-5940-2
Type :
conf
DOI :
10.1109/ISAF.2000.941553
Filename :
941553
Link To Document :
بازگشت