Title
Accuracy aspects in multi-phase flow metering using X-ray transmission
Author
Bom, Victor R. ; Clarijs, Martijin C. ; Van Eijk, Carel W E ; Kolar, Zvonimir I. ; Frieling, Joop ; Scheers, Alex M.
Author_Institution
Interfaculty Reactor Inst., Delft Univ. of Technol., Netherlands
Volume
1
fYear
2000
fDate
2000
Abstract
The composition of a mixture of several components flowing through a pipe can be determined by means of an X-ray transmission technique/analysis. An application is presented in which the component volume fractions of an oil, water and gas mixture are determined. It will be shown that on fundamental grounds this technique has its limits regarding the number of components that can be distinguished, in relation to the achieved accuracy of the measured attenuation
Keywords
X-ray absorption; flowmeters; multiphase flow; X-ray transmission; flow meter; multi-phase flow; oil water gas mixture; Attenuation measurement; Electromagnetic wave absorption; Energy measurement; Equations; Inductors; Petroleum industry; Production; Shape measurement; Telephony; Volume measurement;