Title :
Development of directional neutron detector for compact fast neutron camera
Author :
Iguchi, T. ; Iizuka, S. ; Uritani, A. ; Kawarabayashi, J.
Author_Institution :
Dept. of Nucl. Eng., Nagoya Univ., Japan
Abstract :
A new concept of compact neutron camera with directional neutron detector arrays is proposed for nuclear fusion experiment. The basic performance of the directional neutron detector is made clear through experiment for a prototype detector with 14 MeV neutrons and design consideration of the detector specification to optimize its directionality. The results show that the angle resolution defined as a full width of neutron incident angles at a half maximum of detector counts would reach up to around 4 degrees at minimum around 45 degrees neutron incidence to the detector axis. The concept for a compact neutron camera is also given by making good use of an array of the optimized directional neutron detectors
Keywords :
fusion reactor instrumentation; neutron detection; solid scintillation detectors; 14 MeV; angle resolution; compact fast neutron camera; detector counts; directional neutron detector; directionality; nuclear fusion experiment; Cameras; Collimators; Design optimization; Neutrons; Plasma measurements; Protons; Prototypes; Radiation detectors; Sensor arrays; Telescopes;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2000 IEEE
Conference_Location :
Lyon
Print_ISBN :
0-7803-6503-8
DOI :
10.1109/NSSMIC.2000.949167