Title :
Thermal design and tests for the CMS HCAL readout box
Author :
Baumbaugh, B. ; Baumbaugh, A. ; Booke, M. ; Karmgard, D. ; Los, Sergey ; Lu, Qianxi
Author_Institution :
Notre Dame Univ., IN, USA
Abstract :
A method is necessary to cool the electronics contained in the readout boxes for the CMS HCAL. The electronics to pre-amplify and digitize signals from the optical detectors will generate a large amount of heat that must be removed from the CMS HCAL system. To accomplish this a thermal management system has been designed that uses metallic extrusions, liquid coolant, and thermal foam to transfer the heat from the electronics to the exterior cooling system. Because the electronics are difficult to access throughout the life of the experiment, the temperature must be kept low to extend life expectancy. In order to test the concepts before the final design is implemented a thermal test station was built. Several methods to are under study to determine the best method of making the thermal routing from source of the heat to the liquid for heat removal. The test bed for this evaluation and methods to monitor the electronics temperature in situ are discussed
Keywords :
cooling; nuclear electronics; particle calorimetry; readout electronics; CMS HCAL readout box; life expectancy; liquid coolant; metallic extrusions; thermal foam; thermal management system; Collision mitigation; Coolants; Electronic equipment testing; Electronics cooling; Heat transfer; Optical detectors; Signal generators; Temperature; Thermal management; Thermal management of electronics;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2000 IEEE
Conference_Location :
Lyon
Print_ISBN :
0-7803-6503-8
DOI :
10.1109/NSSMIC.2000.949915