Optimizing Swirlmeter based on Simulation and Experiment
Author
Zhang, Tao ; Jia, Yunfei ; Wu, Lei
Author_Institution
Sch. of Electr. Eng. & Autom., Tianjin Univ.
Volume
1
fYear
0
fDate
0-0 0
Firstpage
4991
Lastpage
4994
Abstract
Swirlmeter is optimized by this way of changing corner dimension between inlet blades and basic shaft from 60deg into 45deg and inlet blades from six into seven. This way is tested by FLUNENT simulation and is examined by experiment in the end. Both simulation and experiment show that not only the pressure loss but also the lowest measuring value of swirlmeter are improved by changing corner dimension. As a result, one of defects of swirlmeter is solved
Keywords
computerised instrumentation; flowmeters; numerical analysis; optimisation; rotational flow; FLUNENT simulation; corner dimension; inlet blades; numerical simulation; pressure loss; swirlmeter optimization; venturi pipe; Automation; Blades; Intelligent control; Loss measurement; Numerical simulation; Pressure measurement; Shafts; Testing; Virtual colonoscopy; numerical simulation; pressure loss; swirler; swirlmeter; venturi pipe;