DocumentCode :
1755639
Title :
Quantitative assessment and comparison of fault responses for synchronous generator and wind turbine generators based on modified transient energy function
Author :
Chowdhury, M.A. ; Weixiang Shen ; Hosseinzadeh, Nasser ; Pota, Hemanshu R.
Author_Institution :
Fac. of Eng. & Ind. Sci., Swinburne Univ. of Technol., Hawthorn, VIC, Australia
Volume :
8
Issue :
5
fYear :
2014
fDate :
41821
Firstpage :
474
Lastpage :
483
Abstract :
This study presents the quantitative transient stability assessment and comparison for conventional synchronous generator (SG) and wind turbine generators (WTGs) by studying the impact of the fault clearing time, the grid coupling, the inertia constant, the generator terminal voltage sag and the slip on fault responses. The assessment and comparison is performed by evaluating the transient stability index through the modified transient energy function. Simulation results show WTGs exhibit different transient responses on the occurrence of faults as compared with conventional SG. This justifies the necessity of study in greater depth for reliable operation of conventional power systems with the integration of large wind power.
Keywords :
power generation faults; power grids; power supply quality; power system transient stability; synchronous generators; transient response; wind power plants; wind turbines; SG; WTG; fault clearing time; fault responses; generator terminal voltage sag; grid coupling; inertia constant; modified transient energy function; quantitative transient stability assessment; synchronous generator; transient stability index; wind power; wind turbine generators;
fLanguage :
English
Journal_Title :
Renewable Power Generation, IET
Publisher :
iet
ISSN :
1752-1416
Type :
jour
DOI :
10.1049/iet-rpg.2012.0323
Filename :
6852013
Link To Document :
بازگشت