DocumentCode :
1756191
Title :
Cross-Strip Multiplexed Electro-Optical Coupled Scintillation Detector for Integrated PET/MRI
Author :
Olcott, P.D. ; Glover, Gary ; Levin, Craig S.
Author_Institution :
Dept. of Bio-Eng., Stanford Univ., Stanford, CA, USA
Volume :
60
Issue :
5
fYear :
2013
fDate :
Oct. 2013
Firstpage :
3198
Lastpage :
3204
Abstract :
A prototype electro-optically coupled PET brain insert is being developed for 1.5 T or 3 T MRI systems. To reduce the number of electronic channels, we developed and tested a novel silicon photomultiplier (SiPM) multiplexing circuit based on a novel cross strip readout circuit using capacitors that reduces the number of channels by a factor of 4. Next, we developed and tested this multiplexing circuit with a new electro-optical coupling method that uses a small vertical cavity surface emitting laser (VCSEL) to transmit the scintillation signal out over fiber. This multiplexing circuit is specially suited for directly driving VCSEL lasers without using preamps or any other active components. Two detectors were placed inside the MR bored, and operated with and without a continuos RF field. We were able to resolve a 6 × 6 array of 2.63 mm × 2.63 mm × 20 mm LYSO crystals that were directly coupled to a 4 × 4 array of 3.2 mm × 3.2 mm SiPM pixels with a global delay corrected paired coincidence time resolution 2.50 +/- 0.015 ns FWHM and a per crystal gain corrected energy resolution of 12.6 +/- 0.6% FWHM @511 keV while operating inside an 1.5 T MRI, with or without the RF field on. The two technologies, capacitive multiplexing and electro-optical coupling, have enabled a high-performance clinical PET detector based on silicon photomultipliers, a factor 4 reduction in the number of readout channels, and, when inserted into a 1.5 T MRI system, has low levels of mutual interference between the PET detector and the MRI.
Keywords :
biomedical MRI; biomedical equipment; brain; capacitors; electro-optical devices; laser applications in medicine; multiplexing; photomultipliers; positron emission tomography; readout electronics; silicon radiation detectors; solid scintillation detectors; surface emitting lasers; FWHM; LYSO crystals; SiPM pixels; VCSEL lasers; capacitive multiplexing coupling; capacitors; cross strip readout circuit; electro-optically coupled PET brain; electronic channels; energy resolution; integrated PET-MRI; magnetic flux density 1.5 T; magnetic flux density 3 T; multiplexed electro-optical coupled scintillation detector; scintillation signal; silicon photomultiplier multiplexing circuit; silicon photomultipliers; vertical cavity surface emitting laser; Detectors; Electrooptical waveguides; Magnetic resonance imaging; Multiplexing; Positron emission tomography; Radio frequency; Vertical cavity surface emitting lasers; Fiber optics; magnetic resonance imaging; nuclear imaging; nuclear medicine; optical interconnections; positron emission tomography;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2013.2271916
Filename :
6583332
Link To Document :
بازگشت