• DocumentCode
    1757317
  • Title

    Adjustable ECR Ion Source Control System: Ion Source Hydrogen Positive Project

  • Author

    Arredondo, I. ; Eguiraun, M. ; Jugo, J. ; Piso, D. ; del Campo, M. ; Poggi, T. ; Varnasseri, S. ; Feuchtwanger, J. ; Bilbao, J. ; Gonzalez, X. ; Harper, G. ; Muguira, L. ; Miracoli, R. ; Corres, J. ; Belver, D. ; Echevarria, P. ; Garmendia, N. ; Gonzalez,

  • Author_Institution
    ESS Bilbao, Leioa, Spain
  • Volume
    62
  • Issue
    3
  • fYear
    2015
  • fDate
    42156
  • Firstpage
    903
  • Lastpage
    910
  • Abstract
    ISHP (Ion Source Hydrogen Positive) project consists of a highly versatile ECR type ion source. It has been built for several purposes, on the one hand, to serve as a workbench to test accelerator related technologies and validate in-house made developments, at the first stages. On the other hand, to design an ion source valid as the first step in an actual LINAC. Since this paper is focused on the control system of ISHP, besides the ion source, all the hardware and its control architecture is presented. Nowadays the ion source is able to generate a pulse of positive ions of Hydrogen from 2 μs to a few ms range with a repetition rate ranging from 1 Hz to 50 Hz with a maximum of 45 mA of current. Furthermore, the first experiments with White Rabbit (WR) synchronization system are presented.
  • Keywords
    ion sources; linear accelerators; plasma accelerators; plasma radiofrequency heating; ECR ion source control system; White Rabbit synchronization system; accelerator related technologies; ion source hydrogen positive project; linac; Control systems; Hardware; Ion sources; Particle beam measurements; Particle beams; Plasmas; Radio frequency; Decentralized control; ion sources;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2015.2432036
  • Filename
    7119617