DocumentCode :
1758929
Title :
Monte Carlo Interpretation of the Photon Heating Measurements in the Integral AMMON/REF Experiment in the EOLE Facility
Author :
Vaglio-Gaudard, C. ; Stoll, K. ; Ravaux, S. ; Lemaire, Martin ; Colombier, A.C. ; Hudelot, J.P. ; Bernard, David ; Amharrak, H. ; Di Salvo, J. ; Gruel, A.
Author_Institution :
DEN, CEA, St. Paul-lez-Durance, France
Volume :
61
Issue :
1
fYear :
2014
fDate :
Feb. 2014
Firstpage :
574
Lastpage :
583
Abstract :
An experiment named AMMON is dedicated to the analysis of the neutron and photon physics of the Jules Horowitz Reactor (JHR). AMMON, performed in the EOLE zero-power experimental reactor at CEA Cadarache, is finished since April 2013. Photon heating measurements were performed with both Thermoluminescent Dosimeters (TLD-400s) and Optically-Stimulated Dosimeters (OSLDs) in three AMMON configurations. The objective is to provide data for the experimental validation of the JHR photon calculation tool. The first analysis of the photon heating measurements of the reference configuration (AMMON/REF) is presented in this paper. The reference configuration consists of an experimental zone of 7 JHR assemblies with U3Si2 - Al 27% 235U enriched fuel curved plates surrounded by a driver zone with 623 standard PWR UOx fuel pins. The photon heating has been measured in the aluminum follower of the central and peripheral assemblies, and in aluminum fillers in the rack between assemblies. The measurement analysis is based on Monte Carlo TRIPOLI-4 ® version 8.1 calculations modeling the core exact three-dimensional geometry. The JEFF nuclear data library is used for the calculation of the neutron transport and the photon emission in the AMMON/REF experiment. The photon transport is made on the basis of the EPDL97 photo-atomic library. The prompt and delayed doses deposited in dosimeters have been estimated separately. The transport of 4 (neutrons, photons, electrons and positrons) or 3 particles (photons, electrons and positrons) is simulated in the calculations for the AMMON/REF analysis, depending whether the prompt or delayed dose is calculated. The TRIPOLI-4.8.1 ® calculations makes it possible the modeling of the electromagnetic cascade shower with both electrons and positrons. The delayed dose represents about 25% of the total photon energy deposition in the dosimeters. The comparison between Calculation and Experiment brings i- to relief a slight systematic underestimation of the calculated global photon energy deposition: (C - E)/E = - 8% ±4.5% (1σ). A special care has been directed towards the determination of the uncertainty associated with the (C-E)/E values. The slight underestimation could be probably explained by an underestimation in the photon emission with the JEFF library.
Keywords :
Monte Carlo methods; fission reactor fuel; fission reactor instrumentation; fission reactor kinetics; fission research reactors; 235U enriched fuel curved plates; AMMON configurations; AMMON-REF analysis; CEA Cadarache; EOLE facility; EOLE zero-power experimental reactor; EPDL97 photo-atomic library; JEFF nuclear data library; JHR assemblies; JHR photon calculation tool; Jules Horowitz Reactor; Monte Carlo TRIPOLI-4® version 8.1 calculations; PWR UOx fuel pins; aluminum fillers; central assemblies; electromagnetic cascade shower; global photon energy deposition; integral AMMON-REF experiment; measurement analysis; neutron physics; neutron transport; optically-stimulated dosimeters; peripheral assemblies; photon emission; photon heating; photon heating measurements; photon physics; thermoluminescent dosimeters; three-dimensional geometry; Assembly; Atmospheric measurements; Calibration; Heating; Neutrons; Nuclear measurements; Photonics; Energy deposition; JHR; Monte Carlo; experimental validation; photonics;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2013.2296356
Filename :
6733439
Link To Document :