ToF Performance Evaluation of PET Modules With Digital Silicon Photomultiplier Technology During MR Operation
Author :
Schug, David ; Wehner, Jakob ; Dueppenbecker, Peter Michael ; Weissler, Bjoern ; Gebhardt, Pierre ; Goldschmidt, Benjamin ; Solf, Torsten ; Kiessling, Fabian ; Schulz, Volkmar
Author_Institution :
Dept. of Phys. of Mol. Imaging Syst., RWTH Aachen Univ., Aachen, Germany
Volume :
62
Issue :
3
fYear :
2015
fDate :
42156
Firstpage :
658
Lastpage :
663
Abstract :
In 2012, we presented the Hyperion-II D preclinical PET insert which uses Philips Digital Photon Counting´s digital SiPMs and is designed to be operated in a 3-T MRI. In this work we use the same platform equipped with scintillators having dimensions closer to a clinical application. This allows an investigation of the time of flight (ToF) performance of the platform and its behavior during simultaneous MR operation. We employ LYSO crystal arrays of 4×4 ×10 mm3 coupled to 4 ×4 PDPC DPC 3200-22 sensors (DPC) resulting in a one-to-one coupling of crystals to read-out channels. Six sensor stacks are mounted onto a singles processing unit in a 2 ×3 arrangement. Two modules are mounted horizontally facing each other on a gantry with a crystal-to-crystal spacing of 217.6 mm (gantry position). A second arrangement places the modules at the maximum distance of approximately 410 mm inside the MR bore (maximum distance position) which brings each module close to the gradient system. The DPCs are cooled down to approximately 5-10° C under operation. We disable 20% of the worst cells and use an overvoltage of Vov = 2.0 V and 2.5 V. To obtain the best time stamps, we use the trigger scheme 1 (first photon trigger), a narrow energy window of 511 ±50 keV and a minimum required light fraction of the main pixel of more than 65% to reject intercrystal scatter. By using a 22Na point source in the isocenter of the modules, the coincidence resolution time (CRT) of the two modules is evaluated inside the MRI system without MR activity and while using highly demanding gradient sequences. Inside the B0 field without any MR activity at an overvoltage of Vov = 2.0 V, the energy resolution is 11.45% (FWHM) and the CRT is 250 ps (FWHM). At an overvoltage of Vov = 2.5 V, the energy resolution is 11.15% (FWHM) and the CRT is 240 ps (FWHM). During a heavy z-gradient seque- ce (EPI factor: 49, gradient strength: 30 mT/m, slew rate: 192.3 mT/m/ms, TE/TR: 12/25 ms and switching duty cycle: 67%) at the gantry position and an overvoltage of Vov = 2.0 V, the energy resolution is degraded relatively by 4.1% and the CRT by 25%. Using the same sequence but at the maximum distance position and an overvoltage of Vov = 2.5 V, we measure a degradation of the energy resolution of 9.2% and a 52% degradation of the CRT. The Hyperion-IID platform proofs to deliver good timing performance and energy resolution inside the MRI system even under highly demanding gradient sequences.
Keywords :
biomedical MRI; biomedical equipment; coincidence techniques; photomultipliers; positron emission tomography; readout electronics; solid scintillation detectors; 22Na point source; Hyperion-II D preclinical PET insert; LYSO crystal arrays; MR gradient sequences; PDPC DPC 3200-22 sensors; PET modules; Philips Digital Photon Counting; ToF performance evaluation; coincidence resolution time; digital SiPM; digital silicon photomultiplier technology; distance 217.6 mm; energy resolution degradation; first photon trigger; heavy z-gradient sequence; intercrystal scatter rejection; magnetic flux density 3 T; minimum required light fraction; one to one crystal-read out channel coupling; overvoltage; scintillators; sensor stacks; simultaneous MR operation; size 10 mm; size 4 mm; time of flight performance; voltage 2.0 V; voltage 2.5 V; Energy resolution; Magnetic resonance imaging; Positron emission tomography; Sensors; Switches; Voltage control; Coincidence techniques; PET; PET instrumentation; digital integrated circuits; digital signal processing; magnetic resonance imaging; medical imaging; scintillation detectors; semiconductor devices; silicon radiation detectors; time resolution; time-of-flight PET;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2015.2396295
Filename :
7056566
Link To Document :
بازگشت