Title : 
Comparison of Three Methods for the Measurement of the Differential Impedance of a Balanced Device [Measurements Corner]
         
        
            Author : 
Zhihong Tu ; Zhang, Yue Ping
         
        
            Author_Institution : 
Sch. of Electron. & Inf. Eng., South China Univ. of Technol., Guangzhou, China
         
        
        
        
        
        
        
        
            Abstract : 
Three methods for the measurement of the differential impedance of a balanced device are evaluated: 1) the S-parameter method, 2) the balun method, and 3) the mixed-mode S-parameter method. An emphasis is given to the choice of combinations of five two-port standards for the balun method. Each of these methods was used to measure the known differential impedance of a broadband balanced load, and the unknown differential impedance of a narrowband balanced microstrip patch antenna. These methods and the obtained experimental results are discussed.
         
        
            Keywords : 
baluns; microstrip antennas; balanced device; balun method; broadband balanced load; differential impedance; mixed-mode S-parameter method; narrowband balanced microstrip patch antenna; three method comparison; Calibration; Impedance; Impedance matching; Microstrip antennas; Scattering parameters; Balanced devices; differential impedance; microstrip antenna;
         
        
        
            Journal_Title : 
Antennas and Propagation Magazine, IEEE
         
        
        
        
        
            DOI : 
10.1109/MAP.2013.6735491