• DocumentCode
    1760835
  • Title

    Force Adaptation in Human Walking With Symmetrically Applied Downward Forces on the Pelvis

  • Author

    Vashista, Vineet ; Agrawal, Nidhi ; Shaharudin, S. ; Reisman, D.S. ; Agrawal, Sunil K.

  • Author_Institution
    Dept. of Mech. Eng., Columbia Univ., New York, NY, USA
  • Volume
    21
  • Issue
    6
  • fYear
    2013
  • fDate
    Nov. 2013
  • Firstpage
    969
  • Lastpage
    978
  • Abstract
    The application of external constraints and/or applied forces during movement can lead to reactive as well as adaptive changes in human motion. Previous research has shown adaptation in walking kinematics when external forces were applied to a leg. This work aims to study adaptation in human walking when externally applied forces were present on the pelvis during the swing and stance phases of both legs. A novel tethered pelvic assist device (TPAD) was used to passively apply symmetric downward forces on the human pelvis while walking. During the experiment, eight healthy subjects walked on a treadmill at a constant speed while their kinematics and foot pressure data were recorded. Data analysis revealed that the healthy subjects exhibited both reactive as well as adaptive changes in their gait parameters. The immediate response of the subjects was to increase their hip flexion to clear their foot off the ground as they were unable to lift their pelvis to their usual height in the presence of downward forces. Seven out of eight subjects resisted the downward forces to move their pelvis up. Eventually, they reached a level of downward force that they could sustain over the training session. This adaptation to the downward force was reflected in the heel peak pressure values during the cycles of the gait. On removing the tethers, aftereffects in heel peak pressure values were observed as a result of higher magnitude of pelvic acceleration in vertical direction. In summary, symmetrically applied external forces on the pelvis of healthy subjects resulted in reactive changes in the gait kinematics and adaptive changes in the gait kinetics and the foot interaction forces with the ground.
  • Keywords
    acceleration measurement; biomedical equipment; biomedical measurement; data analysis; data recording; force measurement; gait analysis; pressure measurement; constant speed; data analysis; externally applied forces; foot interaction forces; foot pressure data recording; force adaptation; gait kinematics; gait parameters; heel peak pressure values; hip flexion; human motion; human walking kinematics; leg; novel tethered pelvic assist device; pelvic acceleration; stance phases; swing phases; symmetrically applied downward forces; symmetrically applied external forces; treadmill; Foot; Force; Hip; Legged locomotion; Pelvis; Springs; Training; Downward forces on pelvis; gait kinetics; passive pelvic device; walking adaptation; Adaptation, Physiological; Adult; Female; Foot; Gait; Humans; Leg; Male; Pelvis; Physical Stimulation; Reference Values; Stress, Mechanical; Walking; Weight-Bearing; Young Adult;
  • fLanguage
    English
  • Journal_Title
    Neural Systems and Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1534-4320
  • Type

    jour

  • DOI
    10.1109/TNSRE.2013.2243917
  • Filename
    6481451