DocumentCode
1762662
Title
Detection of Cardiac Quiescence From B-Mode Echocardiography Using a Correlation-Based Frame-to-Frame Deviation Measure
Author
Wick, C.A. ; McClellan, James H. ; Ravichandran, Lakshminarayan ; Tridandapani, S.
Author_Institution
Sch. of Electr. & Comput. Eng., Georgia Inst. of Technol., Atlanta, GA, USA
Volume
1
fYear
2013
fDate
2013
Firstpage
1900211
Lastpage
1900211
Abstract
Two novel methods for detecting cardiac quiescent phases from B-mode echocardiography using a correlation-based frame-to-frame deviation measure were developed. Accurate knowledge of cardiac quiescence is crucial to the performance of many imaging modalities, including computed tomography coronary angiography (CTCA). Synchronous electrocardiography (ECG) and echocardiography data were obtained from 10 healthy human subjects (four male, six female, 23-45 years) and the interventricular septum (IVS) was observed using the apical four-chamber echocardiographic view. The velocity of the IVS was derived from active contour tracking and verified using tissue Doppler imaging echocardiography methods. In turn, the frame-to-frame deviation methods for identifying quiescence of the IVS were verified using active contour tracking. The timing of the diastolic quiescent phase was found to exhibit both inter- and intra-subject variability, suggesting that the current method of CTCA gating based on the ECG is suboptimal and that gating based on signals derived from cardiac motion are likely more accurate in predicting quiescence for cardiac imaging. Two robust and efficient methods for identifying cardiac quiescent phases from B-mode echocardiographic data were developed and verified. The methods presented in this paper will be used to develop new CTCA gating techniques and quantify the resulting potential improvement in CTCA image quality.
Keywords
angiocardiography; computerised tomography; echocardiography; electrocardiography; B-mode echocardiography; CTCA gating techniques; CTCA image quality; active contour tracking; apical four-chamber echocardiographic view; cardiac quiescent phase detection; computed tomography coronary angiography; correlation-based frame-to-frame deviation measure; interventricular septum; synchronous electrocardiography; tissue Doppler imaging echocardiography; Active contours; Approximation methods; Computed tomography; Coronary angiography; Echocardiography; Electrocardiography; Velocity measurement; Coronary angiography; cardiac gating; computed tomography; echocardiography; electrocardiography;
fLanguage
English
Journal_Title
Translational Engineering in Health and Medicine, IEEE Journal of
Publisher
ieee
ISSN
2168-2372
Type
jour
DOI
10.1109/JTEHM.2013.2291555
Filename
6670044
Link To Document