DocumentCode :
1763301
Title :
Assessment of Early Phase ^{18}{\\rm F} -FP-CIT PET as an Alternative Method of FDG PET for Voxel Based Statistical Analysis: Application for Parkinson\´s Disease Rat Model
Author :
Yu, A.R. ; Jin Su Kim ; Hee-Joung Kim ; Jisook Moon ; Yun Young Choi ; Joo Hyun Kang ; Sang Moo Lim ; Kyeong Min Kim
Author_Institution :
Mol. Imaging Res. Center, Korea Inst. Radiol. & Med. Sci., Seoul, South Korea
Volume :
60
Issue :
2
fYear :
2013
fDate :
41365
Firstpage :
820
Lastpage :
823
Abstract :
18F -FP-CIT PET image was useful for diagnosis of Parkinson´s disease (PD). Although spatial normalization step is necessary in SPM analysis, it was difficult to apply the spatial normalization on 18F-FP-CIT PET due to the lack of reference for spatial normalization. Therefore, additional data acquisition such as MRI or FDG PET scans is needed. In this study, we developed the voxel based statistical analysis method for 18F-FP-CIT PET using early phase of 18F-FP-CIT. 18F-FP-CIT PET data was acquired from 7 normal and 1 PD model rat brain. Emission PET data was collected for 1 h at the start of 1 mCi of 18F-FP-CIT. We used the early phase uptake image (from 0 to 1200 s) including perfusion phase as referential information for spatial normalization. Additionally, 18F-FDG PET was acquired as referential data to validate the substitution of 18F-FP-CIT. To validate early phase 18F-FP-CIT PET data for spatial normalization, correlation coefficient between early phase 18F-FP-CIT and 18F-FDG were assessed. Using our proposed method, SPM for 18F-FP-CIT PET was successfully implemented. Early phase 18F-FP-CIT PET corresponding early phase and 18F-FDG PET were highly correlated. When we applied our developed method for the comparison between normal and PD, we can identify the difference of 18F -FP-CIT between the normal and PD in the striatum (P <; 0.005, K > 0). The SPM method for 18F -FP-CIT PET data could provide high localization accuracy in PD analysis. This method may be useful for assessment of PD.
Keywords :
brain; diseases; medical image processing; positron emission tomography; scanning probe microscopy; statistical analysis; 18F -FP-CIT PET image; 18F-FDG PET; FDG PET scans; MRI scans; Parkinson disease analysis; Parkinson disease rat brain model; SPM analysis; correlation coefficient; early phase 18F-FP-CIT PET data; emission PET data; high localization accuracy; perfusion phase; referential data; spatial normalization step; voxel based statistical analysis method; Animals; Biomedical imaging; Brain modeling; Parkinson´s disease; Positron emission tomography; Statistical analysis; FP-CIT; SPM; positron emission tomography;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2013.2243844
Filename :
6482275
Link To Document :
بازگشت