• DocumentCode
    1764808
  • Title

    Improved Micromachined Terahertz On-Wafer Probe Using Integrated Strain Sensor

  • Author

    Qiang Yu ; Bauwens, Matthew F. ; Chunhu Zhang ; Lichtenberger, Arthur W. ; Weikle, Robert M. ; Barker, N.S.

  • Author_Institution
    Charles L. Brown Dept. of Electr. & Comput. Eng., Univ. of Virginia, Charlottesville, VA, USA
  • Volume
    61
  • Issue
    12
  • fYear
    2013
  • fDate
    Dec. 2013
  • Firstpage
    4613
  • Lastpage
    4620
  • Abstract
    This paper introduces an improved method for monitoring and controlling the contact condition of terahertz on-wafer probes to enhance the measurement repeatability as well as probe lifetime. This method enables accurate contact force and contact angle measurements without modification to the standard probe station. Both probe contact force and contact angle are crucial for RF measurement repeatability. Repeatable probe contact force can be achieved by properly monitoring and controlling the strain generated at designated positions on the terahertz probe due to probe deformation induced by contacting the test substrate. Contact angle can be measured by asymmetrical strain on symmetrical positions of the probe when the probe is contacting the test substrate with angular misalignment. In this work a WR-1.5 (500 GHz-750 GHz) probe with integrated strain sensor is developed and tested. Mechanical tests show that the integrated sensors have a contact force resolution of 0.2 mN and a contact angle resolution of 0.05° about the center. RF tests show that repeatable measurements can be achieved with 3 mN contact force after adjusting probe contact angle using the integrated sensors, as compared to a previously reported value of 15 mN.
  • Keywords
    angular measurement; deformation; force measurement; mechanical testing; micromachining; microsensors; probes; strain sensors; submillimetre wave detectors; submillimetre wave measurement; terahertz wave detectors; thin film sensors; RF measurement repeatability; WR-1.5 probe; angular misalignment; asymmetrical strain; contact condition control; contact condition monitoring; frequency 500 GHz to 750 GHz; integrated strain sensor; mechanical test; micromachined terahertz on-wafer probe; probe contact angle measurement accuracy; probe contact force measurement accuracy; probe deformation; probe lifetime; symmetrical probe position; test substrate; Force; Force measurement; Manganese; Probes; Standards; Strain; Substrates; Micromachining; probes; strain measurement; submillimeter wave measurement; thin film sensors;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9480
  • Type

    jour

  • DOI
    10.1109/TMTT.2013.2288602
  • Filename
    6670737