    Application of wide area measurement systems to islanding detection of bulk power systems

  • Author

    Zhenzhi Lin ; Tao Xia ; Yanzhu Ye ; Ye Zhang ; Lang Chen ; Yilu Liu ; Tomsovic, Kevin ; Bilke, Terry ; Fushuan Wen

  • Author_Institution
    Sch. of Electr. Eng., Zhejiang Univ., Hangzhou, China
  • Volume
    28
  • Issue
    2
  • fYear
    2013
  • fDate
    41395
  • Firstpage
    2006
  • Lastpage
    2015
  • Abstract
    A fast islanding detection tool can help power dispatchers monitor and control power system operations. Frequency monitoring network (FNET) is a low cost and quickly deployable wide-area phasor measurement system at the distribution system level. The frequency disturbance recorder (FDR) in FNET is actually a single-phase phasor measurement unit (PMU) installed at ordinary 120 V outlets in the sense that it measures the voltage phase angle, amplitude, and frequency from a single-phase voltage source. Based on the data collected by the FDRs deployed in the North American power grid, two islanding detection methods, the frequency difference method and the change of angle difference method, are proposed. The nine real cases recorded, including islanding cases, generation trip cases, load shedding cases and oscillation cases, are presented to verify the proposed methods of islanding detection. Sensitivity analysis on the thresholds of the frequency deviation and angle deviation is done based on the real measurement data for obtaining the insensitive interval of two thresholds. The results show that the proposed methods can correctly detect power system islanding, and will not be falsely triggered by generation trips, load shedding and system oscillations.
  • Keywords
    load shedding; phasor measurement; power grids; sensitivity analysis; FNET; North American power grid; angle deviation; angle difference method; bulk power systems; distribution system level; fast islanding detection tool; frequency deviation; frequency difference method; frequency disturbance recorder; frequency monitoring network; generation trip cases; islanding cases; islanding detection methods; load shedding cases; oscillation cases; power dispatchers; power system islanding; power system operations; sensitivity analysis; single-phase phasor measurement unit; single-phase voltage source; system oscillations; voltage 120 V; voltage phase angle; wide area measurement systems; wide-area phasor measurement system; Event detection; Frequency measurement; Phasor measurement units; Wide area measurements; Event detection; frequency disturbance recorder; islanding detection; phasor measurement unit; wide area measurement system;
  • fLanguage
    English
  • Journal_Title
    Power Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8950
  • Type

    jour

  • DOI
    10.1109/TPWRS.2013.2250531
  • Filename
    6482696