• DocumentCode
    1768250
  • Title

    A possibility of using longitudinal balance for qualification and troubleshooting of DSL lines

  • Author

    Skaljo, Namir ; Begovic, Alen ; Behlilovic, Narcis

  • Author_Institution
    Directorate Zenica, BH Telecom J.S.C., Zenica, Bosnia-Herzegovina
  • fYear
    2014
  • fDate
    27-29 Oct. 2014
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    This paper examines the actual usefulness and importance of longitudinal balance as one of many electrical parameters of symmetrical copper pairs. Through the results of several experiments on copper pairs with different types of significant faults, but also by measuring longitudinal balance on the real system in practice, this paper attempts to show the actual usefulness and importance of this parameter. In this manner, this paper intends to make the process of measuring the electrical parameters of symmetrical copper pairs more reliable and usable for reliable detection of various types of faults.
  • Keywords
    digital subscriber lines; fault diagnosis; parameter estimation; telecommunication network reliability; DSL line troubleshooting; digital subscriber line qualification; fault reliable detection; symmetrical copper pair electrical parameter longitudinal balance; Copper; DSL; Electrical resistance measurement; Insulation; Resistance; Wires; DSL line; copper pair; detection of problems; electrical parameters; faults; longitudinal balance; measuring of electrical parameters; physical layer parameters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Telecommunications (BIHTEL), 2014 X International Symposium on
  • Conference_Location
    Sarajevo
  • Print_ISBN
    978-1-4799-8038-3
  • Type

    conf

  • DOI
    10.1109/BIHTEL.2014.6987638
  • Filename
    6987638