In this paper, at first the term and the technical significance of the degree of polymerization (DP) of cellulose insulation is explained. Factors influencing the DP of new, unused insulation products are detailed. An overview of commonly used DP measuring techniques and standards is given. Depending on the method, the measured DP value of cellulose insulation can vary considerably. The DP loss at transformer drying in the factory is examined and the correlation of the DP with functional properties and lifetime of solid insulation is detailed. The issue of minimum DP requirement of insulation of new transformers is discussed, considering the assessed loss-of-life due to transformer drying.
Keywords
drying; organic insulating materials; polymerisation; power transformer insulation; DP measuring technique; cellulosic insulation; degree of polymerization; loss-of-life assessment; solid insulation lifetime; transformer drying; transformer insulation; Aging; Oil insulation; Polymers; Power transformer insulation; Viscosity; DP; cellulose; degree of polymerization; drying; insulation; lifetime; loss-of-life; transformer;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation Conference (EIC), 2014
Conference_Location
Philadelphia, PA
Print_ISBN
978-1-4799-2787-6
Type
conf
DOI
10.1109/EIC.2014.6869389
Filename
6869389
Link To Document