• DocumentCode
    1773298
  • Title

    The degree of polymerization of cellulosic insulation: Review of measuring technologies and its significance on equipment

  • Author

    Krause, Christoph ; Dreier, L. ; Fehlmann, A. ; Cross, James Dorian

  • Author_Institution
    WEIDMANN Electr. Technol. AG, Rapperswil, Switzerland
  • fYear
    2014
  • fDate
    8-11 June 2014
  • Firstpage
    267
  • Lastpage
    271
  • Abstract
    In this paper, at first the term and the technical significance of the degree of polymerization (DP) of cellulose insulation is explained. Factors influencing the DP of new, unused insulation products are detailed. An overview of commonly used DP measuring techniques and standards is given. Depending on the method, the measured DP value of cellulose insulation can vary considerably. The DP loss at transformer drying in the factory is examined and the correlation of the DP with functional properties and lifetime of solid insulation is detailed. The issue of minimum DP requirement of insulation of new transformers is discussed, considering the assessed loss-of-life due to transformer drying.
  • Keywords
    drying; organic insulating materials; polymerisation; power transformer insulation; DP measuring technique; cellulosic insulation; degree of polymerization; loss-of-life assessment; solid insulation lifetime; transformer drying; transformer insulation; Aging; Oil insulation; Polymers; Power transformer insulation; Viscosity; DP; cellulose; degree of polymerization; drying; insulation; lifetime; loss-of-life; transformer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference (EIC), 2014
  • Conference_Location
    Philadelphia, PA
  • Print_ISBN
    978-1-4799-2787-6
  • Type

    conf

  • DOI
    10.1109/EIC.2014.6869389
  • Filename
    6869389