    This paper presents the efficient limit setting for state of charge (SOC) to match with respect to the solar irradiance, load condition while special consideration based on analyzing the number of operational hours of diesel generator and lifetime of the battery. The hybrid PV/diesel standalone system is located in Ranau, Sabah, Malaysia.
  • Keywords
    diesel-electric generators; hybrid power systems; photovoltaic power systems; Sabah Malaysia; diesel generator; hybrid PV-diesel system; load condition; solar irradiance; state of charge; storage capacity; Batteries; Bidirectional control; Inverters; Photovoltaic systems; System-on-chip; Hybrid Photovoltaic System; Performance ratio; Photovoltaic Monitoring; Solar Photovoltaic System;