DocumentCode
1773818
Title
Investigation of calculation method of losses in PWM inverter with voltage booster using both DC link voltage Control and flux weakening control
Author
Imakiire, Akihiro ; Hikita, Masayuki ; Yamamoto, Koji ; Yonemori, Ryo
Author_Institution
Dept. of Electr. & Electron. Eng., Kyushu Inst. of Technol., Kitakyushu, Japan
fYear
2014
fDate
18-21 May 2014
Firstpage
689
Lastpage
693
Abstract
In this paper, authors investigate calculation method of losses in system which consists of interior permanent magnet (IPM) motor and PWM inverter with voltage booster. This system has two driving methods for motor in high speed region. One is DC link voltage Control. The other is flux weakening control. However, it is not cleared how combination of these two control methods is suitable for this system. It is necessary to quantitatively estimate parts of system losses in voltage booster, inverter and IPM motor, because total efficiency of system is decided by parts of system losses. So, the simulation model, which is capable of calculating parts of system losses to find suitable driving method for IPM motor using combination of the two control methods, is introduced and simulation results are discussed.
Keywords
PWM invertors; magnetic flux; permanent magnet motors; voltage control; DC link voltage Control; IPM motor; PWM inverter; flux weakening control; interior permanent magnet motor; voltage booster; DC motors; Inductors; Inverters; Pulse width modulation; Standards; Switches; Voltage control; DC link voltage control; flux weakening control; interior permanent magnet motor; voltage booster;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE-ASIA), 2014 International
Conference_Location
Hiroshima
Type
conf
DOI
10.1109/IPEC.2014.6869662
Filename
6869662