DocumentCode
1774468
Title
DCM control method of boost converter based on conventional CCM control
Author
Le Hoai Nam ; Orikawa, Koji ; Itoh, Jun-ichi
Author_Institution
Dept. of Electr., Electron. & Inf. Eng., Nagaoka Univ. of Technol., Nagaoka, Japan
fYear
2014
fDate
18-21 May 2014
Firstpage
3659
Lastpage
3666
Abstract
This paper proposes current control method for DCM to achieve same control performance as CCM. The proposed control loop is designed based on the conventional current control loop in CCM. By using only one PI controller and introduction of two correction factors, the proposed control method can control both CCM and DCM current exactly to design values. In this paper, the operation of the proposed control method is confirmed by simulation and experiment. The simulation results of the current response in both CCM and DCM agree with design values. In the experimental results, due to the delay in feedback, error 11.3% in rise time and error 2.5 point in overshoot occur. Furthermore, the voltage regulation experiment with the proposed current controller as a inner control loop is conducted. As load varies, the recovery time for the output voltage regulation is about 20 ms and the overshoot - undershoot voltage is below 3%.
Keywords
PI control; closed loop systems; electric current control; power convertors; power factor correction; voltage control; DCM control method; PI controller; boost converter; conventional CCM control; correction factor; current control loop design; current control method; recovery time; voltage regulation; Feedforward neural networks; Manganese; Transfer functions;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE-ASIA), 2014 International
Conference_Location
Hiroshima
Type
conf
DOI
10.1109/IPEC.2014.6870024
Filename
6870024