Title :
Third harmonic measurement in printed electronics
Author :
Samano, A. ; Xu, Yan ; Harrison, Dew ; Hunt, C. ; Wickham, M. ; Thomas, O.
Author_Institution :
Sch. of Eng. & Design, Brunel Univ., Uxbridge, UK
Abstract :
The purpose of this research paper is to investigate the defects detecting technique in printed electronics by the third harmonic measurements. Various types of defects were introduced on the samples and the third harmonic signal was measured using a component linearity tester (Radiometer CLT1). The relationship between the defects in the printed samples and the third harmonic signal and the third harmonic ratio was identified.
Keywords :
circuit reliability; printed circuit testing; Radiometer CLT1; component linearity tester; defect detecting technique; printed electronics; third harmonic measurement; third harmonic ratio; third harmonic signal; Frequency measurement; Harmonic analysis; Ink; Pollution measurement; Reliability; Resistors; Semiconductor device measurement; defect detection; printed electronics; reliability testing; third harmonic index;
Conference_Titel :
Antennas and Propagation (APCAP), 2014 3rd Asia-Pacific Conference on
Conference_Location :
Harbin
Print_ISBN :
978-1-4799-4355-5
DOI :
10.1109/APCAP.2014.6992642