Abstract
This paper presents the series connected wound rotor three phase induction motor, SCIM, research work previously reported in the literature with highlights on its performance characteristics, stability and the comparisons drawn with the conventional induction motor. Simulated results of the transient behavior of the SCIM are shown under different load conditions and a sequence of disruptive conditions, ex. unbalance supply, single phase to ground fault, open circuited phase and sudden phase reversal fault. The results confirm the sensitivity of such mode of operation under load and disruptive conditions.
Keywords
fault diagnosis; induction motors; rotors; stability; transient analysis; SCIM; disruptive conditions; load conditions; performance characteristics; series connected wound rotor; stability; three phase induction motor; transient behavior; Induction motors; Rotors; Stator windings; Synchronous motors; Torque; Windings; fault conditions; induction motor; overvoltage operation; series rotor connection;