Abstract
Active Power Filters are developed for compensating the harmonics, reactive power simultaneously. The performance of shunt Active Power Filter depends on the two factors i.e., type of the controller and methods used to obtain the reference current. Generally, the type of controller used in most of the Active Power Filters is traditional PI controller or Fuzzy Logic Controller. Recently, Fault Tolerant Shunt Active Power Filter was proposed using PI controller with redundancy method to guarantee reliability of Active Power Filters. However in this study, we propose a Fault tolerant Shunt Active Power Filter using Fuzzy Logic Controller instead of PI controller to achieve better performance in terms of Total Harmonic Distortion. Simulation results are obtained using MATLAB/SIMULINK for Fuzzy based Fault tolerant Shunt Active Power Filter in presence of open / short circuit fault and shown better results in comparison with Fault Tolerant Shunt Active Filter using PI controller.
Keywords
active filters; fault tolerance; fuzzy control; harmonic distortion; power harmonic filters; MATLAB; PI controller; SIMULINK; fuzzy based fault tolerant shunt active power filter; fuzzy logic controller; open circuit fault; short circuit fault; total harmonic distortion; Active filters; Circuit faults; Fault tolerance; Fault tolerant systems; Fuzzy logic; Power harmonic filters; Active Power Filter; Fault; Fuzzy; PI contriller;
fLanguage
English
Publisher
ieee
Conference_Titel
Control, Instrumentation, Communication and Computational Technologies (ICCICCT), 2014 International Conference on
Conference_Location
Kanyakumari
Print_ISBN
978-1-4799-4191-9
Type
conf
DOI
10.1109/ICCICCT.2014.6993169
Filename
6993169
Link To Document