• DocumentCode
    1776673
  • Title

    Impact of generator control parameters on wind generator fault detection

  • Author

    Zaggout, M.N. ; Elsherif, M.A. ; Yahia, F.Z.

  • Author_Institution
    Dept. of Electr. Eng., Misurata Univ., Misurata, Libya
  • fYear
    2014
  • fDate
    24-25 Sept. 2014
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    This paper presents deep investigation of the generator control parameters impact on the detection of rotor electrical asymmetry in wind turbine doubly fed induction generator. This impact cannot be ignored when the fault detection is based on the analysis of d- and q-rotor current error signals inside the rotor side inverter controller. In order to evaluate the effectiveness of these signals as diagnostic indexes to rotor fault in respect to different values of the control parameters, several simulation and experimental tests were carried out. Results are presented to demonstrate the sensitivity of the d- and q-rotor current error signals for rotor electrical asymmetry detection in comparison with previous stator current and total power analysis methods.
  • Keywords
    asynchronous generators; electric current control; fault diagnosis; invertors; machine control; rotors; wind turbines; d-rotor current error signals; diagnostic indexes; fault detection; generator control parameters impact; q-rotor current error signals; rotor electrical asymmetry detection; rotor fault; rotor side inverter controller; wind turbine doubly fed induction generator; Wind power; control loop signals; fault detection sensitivity; rotor electrical asymmetry;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Renewable Power Generation Conference (RPG 2014), 3rd
  • Conference_Location
    Naples
  • Type

    conf

  • DOI
    10.1049/cp.2014.0833
  • Filename
    6993226