The Application of LRL Technique for Calibrating the Automatic Network Analyzer
Author
Cao Yun ; Chen Huaiyan
Author_Institution
Dept. of Meas., Beijing Aerosp. Control Center, Beijing, China
fYear
2014
fDate
18-20 Sept. 2014
Firstpage
265
Lastpage
268
Abstract
LRL technique for calibrating the automatic network analyzer is presented. LRL technique is a variation of TRL, it is especially useful for microwave, non-coaxial environments. This technique would enhance the accuracy extent of calibration. Detailed information about the choice of LRL calibration kits and LRL calibration steps are given. In addition, an measurement example using LRL calibration approves LRL technique is valid.
Keywords
calibration; measurement errors; measurement uncertainty; network analysers; LRL calibration technique; automatic network analyzer; measurement accuracy; measurement errors; Accuracy; Calibration; Frequency measurement; Measurement uncertainty; Standards; Transmission line matrix methods; Transmission line measurements; LRL; air line; calibration; error model; measurement;