Abstract :
There are several standards that recommend the use of transmission line systems (TLS) as the field generation equipment for immunity testing. In general the assumption is that these systems provide a uniform field that will illuminate the whole vehicle under test. Additionally, It is commonly assumed that these systems do not radiate and that the shielded semi-anechoic chamber has no effect on their performance. In this paper the reader will be educated on two facts. First, that the TEM field supported by these structures is not perfectly uniform over the volume occupied by the vehicle at all frequencies. Second, that the structure will radiate and that it will couple to the chamber enclosure. The coupling will produce potential resonances at certain frequencies depending on the size of the chamber.
Keywords :
anechoic chambers (electromagnetic); immunity testing; transmission lines; TEM field; TLS; chamber enclosure; field generation equipment; full vehicle immunity testing; large E field generators; potential resonances; shielded semi-anechoic chamber; transmission line systems; vehicle under test; Generators; ISO standards; Immunity testing; Resonant frequency; Vehicles; Automotive EMC; Immunity; TEM Devices;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, Tokyo (EMC'14/Tokyo), 2014 International Symposium on
Conference_Location :
Tokyo
Type :
conf
Filename :
6997236
Link To Document :
بازگشت