DocumentCode
1784613
Title
A differential method of high-frequency magnetics core loss test scheme
Author
Ye Jianying ; Chen Wei ; He Jiannong
Author_Institution
Fuzhou Univ., Fuzhou, China
fYear
2014
fDate
24-27 June 2014
Firstpage
1
Lastpage
5
Abstract
Because of its inherent drawbacks, the conventional AC power meter method for magnetics core loss has been limited in some case. A new method based on testing the input power difference with and without the DUT core in the circuit is proposed and it is called as differential method in this paper. The new method eliminates the problem of high errors with AC power meter method due to the phase shift error in the condition of high frequencies and high DUT impedance angles. Its suitable applications are described and analyzed deeply. The test scheme and circuits are also presented which is especially appropriate for the core loss tests with low-frequency current bias, such as in the PFC inductors. Measured results verify the accuracy of the technique by calorimetric method.
Keywords
eddy current losses; loss measurement; magnetic cores; magnetic leakage; power convertors; power meters; testing; AC power meter method; PFC inductors; calorimetric method; differential method; high DUT impedance angles; high-frequency magnetic core loss test scheme; input power difference testing; low-frequency current bias; phase shift error; Core loss; Frequency measurement; Inductors; Loss measurement; Magnetic cores; Windings; core-loss; difference; magnetics; power converter; test;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics for Distributed Generation Systems (PEDG), 2014 IEEE 5th International Symposium on
Conference_Location
Galway
Type
conf
DOI
10.1109/PEDG.2014.6878678
Filename
6878678