DocumentCode :
1787701
Title :
Fast and accurate emissivity and absolute temperature maps measurement for integrated circuits
Author :
Hsueh-Ling Yu ; Yih-Lang Li ; Tzu-Yi Liao ; Tianchen Wang ; Yiyu Shi ; Shu-Fei Tsai
Author_Institution :
CMS/Ind. Technol. Res. Inst., Hsinchu, Taiwan
fYear :
2014
fDate :
2-6 Nov. 2014
Firstpage :
542
Lastpage :
549
Abstract :
The comparison of temperatures (temperature correlation) obtained by measuring instruments and by thermal simulation is commonly necessary. Currently the way in which thermal maps are obtained by infrared thermographer yields inaccurate results since the emissivity values of all elements in an IC are ignored and measurement method assumes a constant emissivity. Without the correct settings of emissivity in infrared thermographer, the temperature variation could reach up to as high as 300 %. Coating black paint on the IC surface is a widely used method to assume the IC with constant emissivity and simplify the measurement procedures. Coating a uniform black thin film on an IC is a highly skillful technique and the coated black paint is un-removable. In certain cases, it is not convenient or possible to do so - for example, as monitoring a working chip. This article proposes the first practical and feasible method for emissivity map measurement. Two reference plates are utilized to obtain an emissivity map, from which real emissivity value of each pixel of the infrared thermographer is obtained. Firstly the radiances of IC and two reference plates are measured by the infrared thermographer. After that, the emissivity map of the IC can be calculated by the radiances. According to the experimental results herein, the uncertainty in the emissivity measured using this method is very low, of the order of 0.01, consistent with the minimum resolution of all currently available infrared thermographic instruments. With the emissivity map, the high accuracy temperature map is then obtained. The comparison of the temperature maps simulated by the extend version of Noxim (Access Noxim) as well as measured by the thermographer with constant emissivity and with the accurate emissivity map are presented in this article. This work contributes to the field of thermal analysis and simulation. Accurate circuit characteristics can be obtained through accurate thermal map; on the other h- nd, the closeness between the thermal simulation result and the real thermal map can also be realized.
Keywords :
infrared imaging; integrated circuit packaging; spectral methods of temperature measurement; thermal analysis; thermal management (packaging); Access Noxim; absolute temperature map measurement; accurate thermal map; circuit characteristics; emissivity map measurement; emissivity measurement uncertainty; infrared thermographer; integrated circuits; reference plates; temperature correlation; thermal analysis; thermal simulation; Coatings; Integrated circuits; Materials; Surface treatment; Temperature distribution; Temperature measurement; Wavelength measurement; emissivity; infrared thermographer; radiance; temperature map;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Computer-Aided Design (ICCAD), 2014 IEEE/ACM International Conference on
Conference_Location :
San Jose, CA
Type :
conf
DOI :
10.1109/ICCAD.2014.7001403
Filename :
7001403