DocumentCode :
1787910
Title :
Increase of separation efficiency in the inertial gas-purifying equipment by high-intensity ultrasonic vibrations
Author :
Khmelev, Vladimir N. ; Shalunov, Andrey V. ; Nesterov, Victor A. ; Golykh, Roman N. ; Dorovskikh, Roman S.
Author_Institution :
Biysk Technol. Inst. (branch), Altay State Tech. Univ. named after I.I. Polzunov, Biysk, Russia
fYear :
2014
fDate :
June 30 2014-July 4 2014
Firstpage :
233
Lastpage :
239
Abstract :
This article describes the prospects of applying of ultrasonic vibrations to increase efficiency of gas-dispersed flow separation on the example of the vortex tube. Developed model of the separation of gas-dispersed flow containing solid particles is described. The specific feature of the model is in consideration of particle coagulation caused by high-intensity ultrasonic vibrations. The characteristics of the gas flow and ultrasonic influence providing minimum separation time of solid fine particles and continuous phase are determined.
Keywords :
flow separation; pipe flow; production equipment; purification; vibrations; vortices; continuous phase; flow separation efficiency; gas-dispersed flow separation; high-intensity ultrasonic vibrations; inertial gas purifying equipment; particle coagulation; solid fine particles; vortex tube; Acoustics; Coagulation; Electron tubes; Fluid flow; Force; Time-frequency analysis; Vibrations; Ultrasound; gas-purifying equipment; separation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Micro/Nanotechnologies and Electron Devices (EDM), 2014 15th International Conference of Young Specialists on
Conference_Location :
Novosibirsk
ISSN :
2325-4173
Print_ISBN :
978-1-4799-4669-3
Type :
conf
DOI :
10.1109/EDM.2014.6882519
Filename :
6882519
Link To Document :
بازگشت