DocumentCode :
1803070
Title :
Investigation of long-pulse plasma immersion ion implantation
Author :
Zeng, X. ; Fu, R.K.Y. ; Chu, P.K.
Author_Institution :
City Univ. of Hong Kong, China
fYear :
2001
fDate :
17-22 June 2001
Firstpage :
389
Abstract :
Summary form only given, as follows. In conventional plasma immersion ion implantation (PIII), the voltage pulse duration is typically on the order of a few tens of microseconds. However, a longer pulse width brings a number of advantages to the hydrogen PIII/ion-cut and water PIII processes, for example. They include reduction of surface hydrogen, implantation damage, and metallic contamination. We present our results on long-pulse PIII. The simulation and experiments are conducted using a conducting grid separating the vacuum chamber into two zones. The grids confines the plasma sheath and allow long-pulse PIII experiments without premature plasma extinction. We measure the expansion of the plasma sheath and plasma recovery time by monitoring the electron saturation current using a Langmuir probe. We also determine the in-depth distribution and uniformity of the implanted hydrogen as well as the voltage/current waveforms. Our investigation indicates that long-pulse PIII can be realized in a conventional PIII chamber and the practical pulse width can be higher than 500 microseconds because the grid stops the expansion of the plasma sheath. It implies that the dimension of the vacuum chamber does not constitute a limiting factor. The calculated maximum pulsing frequency is about 1 kHz that is limited by the plasma recovery time. A practical pulse duration is between 100 and 500 microseconds. Our results also show improvement in the ion energy distribution under this operation mode.
Keywords :
Langmuir probes; ion implantation; plasma materials processing; plasma sheaths; reduction (chemical); surface chemistry; 1 kHz; 100 to 500 mus; 500 mus; H; H plasma immersion implantation process; H/sub 2/O; Langmuir probe; conducting grid; conventional plasma immersion ion implantation; electron saturation current; expansion; experiments; implantation damage; in-depth distribution; ion energy distribution; limiting factor; long-pulse plasma immersion implantation; maximum pulsing frequency; metallic contamination; operation mode; plasma recovery time; plasma sheath; practical pulse width; premature plasma extinction; pulse duration; pulse width; reduction; simulation; surface H; uniformity; vacuum chamber; voltage pulse duration; voltage/current waveforms; water plasma immersion implantation process; Hydrogen; Plasma confinement; Plasma immersion ion implantation; Plasma measurements; Plasma sheaths; Plasma simulation; Plasma waves; Space vector pulse width modulation; Voltage; Water pollution;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Pulsed Power Plasma Science, 2001. IEEE Conference Record - Abstracts
Conference_Location :
Las Vegas, NV, USA
Print_ISBN :
0-7803-7141-0
Type :
conf
DOI :
10.1109/PPPS.2001.961113
Filename :
961113
Link To Document :
بازگشت