• DocumentCode
    1804915
  • Title

    Use of the VHF detection technique for PD pattern analysis on turbogenerators

  • Author

    Zondervan, J.P. ; Gulski, E. ; Smit, J.J. ; Brooks, R.

  • Author_Institution
    High Voltage Lab., Delft Univ. of Technol., Netherlands
  • Volume
    1
  • fYear
    1998
  • fDate
    7-10 Jun 1998
  • Firstpage
    274
  • Abstract
    Partial discharge (PD) patterns measured in turbogenerators have been evaluated using the VHF PD detection technique. Two aspects of on-line PD measurements are discussed here: 1. Analysis of the frequency behavior of particular phases over time. 2. Evaluation of each phase´s contribution to PD patterns of other phases over time
  • Keywords
    insulation testing; machine insulation; machine testing; partial discharge measurement; stators; turbogenerators; VHF detection; on-line PD measurement; partial discharge; pattern analysis; stator insulation; turbogenerator; Frequency measurement; Insulation; Partial discharges; Pattern analysis; Phase detection; Phase measurement; Resonance; Resonant frequency; Time measurement; Turbogenerators;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 1998. Conference Record of the 1998 IEEE International Symposium on
  • Conference_Location
    Arlington, VA
  • ISSN
    1089-084X
  • Print_ISBN
    0-7803-4927-X
  • Type

    conf

  • DOI
    10.1109/ELINSL.1998.704718
  • Filename
    704718