Title :
Gas breakdown in the sub-nanosecond regime with voltages below 15 kV
Author :
Krompholz, H.G. ; Hatfield, L.L. ; Kristiansen, M. ; Short, B.
Author_Institution :
Texas Tech Univ., Lubbock, TX, USA
Abstract :
Summary form only given, as follows. Gaseous breakdown in the sub-nanosecond regime is of interest for fast pulsed power switching, short pulse electromagnetics, and for plasma limiters to protect devices from high power microwave radiation. Previous investigations of sub-nanosecond breakdown were mainly limited to high pressure gases or liquids, with applied voltages in excess of 100 kV. We investigate the possibilities to achieve sub-nanosecond breakdown at applied voltages below 7.5 kV in point-plane geometries. The setup consists of a pulser (risetime between 400 ps to 1 ns), 50-Ohm transmission line, axial needle-plane gap with outer coaxial conductor, and a 50-Ohm load line. The needle consists of tungsten and has a radius of curvature below 0.5 mm. The constant system impedance of 50 Ohm (except in the vicinity of the gap) and a special transmission-line-type current sensors enables current and voltage measurements with a dynamic range covering several orders of magnitude, with temporal resolutions down to 80 ps. For pulse amplitudes of 1.7 kV (which are doubled at the open gap before breakdown) delay times between start of the pulse and start of a measurable current flow (amplitude > several milliamperes) have a minimum of about 8 ns, at a pressure of 50 torr in argon. Voltages of 7.5 kV produce breakdowns with a delay of about 1 ns. With negative pulses applied to the tip, at an amplitude of 7.5 kV, breakdown is always observed during the rising part of the pulse, with breakdown delay times below 800 ps, at pressures between 1 and 100 torr. At lower pressure, a longer delay time (8 ns at 50 mtorr) is observed. We expect the breakdown mechanism to be dominated by electron field emission, but still influenced by gaseous amplification.
Keywords :
argon; electric breakdown; electric current measurement; electric sensing devices; plasma diagnostics; voltage measurement; 1 to 100 torr; 1.7 kV; 100 kV; 15 kV; 400 ps to 1 ns; 50 mtorr; 50 ohm; 50 torr; 7.5 kV; 8 ns; 80 ps; 800 ps; Ar; W; applied voltages; axial needle-plane gap; breakdown; breakdown delay times; breakdown mechanism; breakdowns; constant system impedance; current flow; current measurements; delay time; delay times; dynamic range; electron field emission; fast pulsed power switching; gas breakdown; gaseous amplification; high power microwave radiation; high pressure gases; high pressure liquids; load line; negative pulses; open gap; outer coaxial conductor; plasma limiters; point-plane geometries; pressures; pulse amplitudes; pulser; radius of curvature; risetime; short pulse electromagnetics; sub-nanosecond breakdown; sub-nanosecond regime; temporal resolutions; transmission line; transmission-line-type current sensors; voltage measurements; voltages; Breakdown voltage; Delay; Electric breakdown; Electromagnetic devices; Electromagnetic radiation; Gases; Microwave devices; Plasma devices; Protection; Pulse measurements;
Conference_Titel :
Pulsed Power Plasma Science, 2001. IEEE Conference Record - Abstracts
Conference_Location :
Las Vegas, NV, USA
Print_ISBN :
0-7803-7141-0
DOI :
10.1109/PPPS.2001.961234