Title :
Instrument transformer performance under distorted-conditions
Author :
Mahesh, G. ; George, Boby ; Jayashankar, V. ; Kumar, Jagadeesh V.
Author_Institution :
Centre for Electromagn., SAMEER, Chennai, India
Abstract :
Current transformers (CT) and voltage transformers (VT) are the primary sensing elements in electric power systems. While their performance at a single frequency is well known, it is necessary to analyze the performance of CTs and VTs for harmonic excitation. A single virtual instrument that can be used for performance measurements of instrument transformers (IT) in addition to analyzing the magnetic characteristics of cores is proposed. Experimental results are shown to validate the proposed method.
Keywords :
current transformers; harmonic distortion; instrument transformers; potential transformers; power system harmonics; power system measurement; virtual instrumentation; CT; IT; VT; core magnetic characteristics; current transformer; distorted-condition; electric power system; harmonic excitation; instrument transformer performance; primary sensing element; voltage transformer; Current transformers; Frequency; Harmonic analysis; Instrument transformers; Magnetic analysis; Measurement; Performance analysis; Power system harmonics; Transformer cores; Voltage transformers;
Conference_Titel :
India Annual Conference, 2004. Proceedings of the IEEE INDICON 2004. First
Print_ISBN :
0-7803-8909-3
DOI :
10.1109/INDICO.2004.1497797