On the Laplacian inverse electrocardiography
Author :
He, Bin
Author_Institution :
Div. of Health Sci. & Technol., MIT, Cambridge, MA, USA
fYear :
1994
fDate :
3-6 Nov 1994
Firstpage :
145
Abstract :
The author introduces a concept for a new approach in inverse electrocardiography. Body surface Laplacian electrograms, instead of potential electrograms, are employed to reconstruct the epicardial equivalent source distributions. The author tested this idea by means of computer simulation studies using a concentric spheres volume conductor model. The present computer simulation results suggest that the epicardial potential inverse solution from the body surface Laplacian map has a higher reconstruction precision and a greater stability than the inverse solution from the body surface potential map for the myocardial source configurations studied
Keywords :
digital simulation; electrocardiography; inverse problems; Laplacian inverse electrocardiography; body surface Laplacian electrograms; body surface potential map; concentric spheres volume conductor model; epicardial equivalent source distributions; myocardial source configurations; potential electrograms; reconstruction precision; solution stability; Computer simulation; Conductors; Electrocardiography; Inverse problems; Laplace equations; Myocardium; Noise level; Stability; Surface reconstruction; Testing; Torso;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 1994. Engineering Advances: New Opportunities for Biomedical Engineers. Proceedings of the 16th Annual International Conference of the IEEE
Conference_Location :
Baltimore, MD
Print_ISBN :
0-7803-2050-6
Type :
conf
DOI :
10.1109/IEMBS.1994.411790
Filename :
411790
Link To Document :
بازگشت