• DocumentCode
    1811974
  • Title

    Inverting mode failure recovery: application to the drive of a DC generator supplied by a three-phase thyristor converter

  • Author

    Sawicki, J.-P. ; Zanne, C. ; Aubry, J.-F.

  • Author_Institution
    CRAN, ENSEM, Vandoeuvre-les-Nancy, France
  • fYear
    1995
  • fDate
    28-29 Sep 1995
  • Firstpage
    383
  • Lastpage
    388
  • Abstract
    In this paper, we present a new control strategy for industrial applications with static converters. It is based on a reconfiguration of the firing sequence and on a resetting of a digital controller. Applied to the nonautonomous inverting mode it allows guarantee of a maximal efficiency without decreasing the dependability of the electromechanical process
  • Keywords
    thyristor convertors; DC generator drive; DC motors; digital controller resetting; electromechanical process dependability; firing sequence reconfiguration; inverting mode failure recovery; maximal efficiency; nonautonomous inverting mode; static converters; three-phase thyristor converter; Bridge circuits; Commutation; Control systems; Fault detection; Image sensors; Industrial control; Optical sensors; Synchronous motors; Thyristors; Torque control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control Applications, 1995., Proceedings of the 4th IEEE Conference on
  • Conference_Location
    Albany, NY
  • Print_ISBN
    0-7803-2550-8
  • Type

    conf

  • DOI
    10.1109/CCA.1995.555734
  • Filename
    555734