• DocumentCode
    1812293
  • Title

    Impact of the transformer in the current mode supply of dielectric barrier discharge excimer lamps

  • Author

    Florez, David ; Bonnin, Xavier ; Diez, Rafael ; Piquet, Hubert

  • Author_Institution
    Dept. of Electron., Pontificia Univ., Toulouse, France
  • fYear
    2013
  • fDate
    27-31 Oct. 2013
  • Firstpage
    1171
  • Lastpage
    1176
  • Abstract
    This paper presents an analysis of the consequences of using a step-up transformer in the supply of a dielectric barrier discharge (DBD) excimer lamp. A simplified transformer model is used to analyze the effects of the different parasitic elements in the operation of a current mode power supply. Mathematical expressions are found for each element and experimental validation is performed. The design of the transformer is developed on the basis of the lamp specifications and two transformer configurations are tested experimentally, analyzing the effect of the parasitic elements and evidencing the influence of grounding a lamp terminal.
  • Keywords
    discharge lamps; power supply circuits; transformers; DBD excimer lamps; current mode power supply; dielectric barrier discharge; lamp terminal; simplified transformer model; step-up transformer; Capacitance; Dielectrics; Impedance; Inverters; Power supplies; Power transformer insulation; Windings; Dielectric barrier discharge; Gas discharge devices; Plasma sources; Power supply; Transformer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Conference (COBEP), 2013 Brazilian
  • Conference_Location
    Gramado
  • ISSN
    2175-8603
  • Type

    conf

  • DOI
    10.1109/COBEP.2013.6785263
  • Filename
    6785263