• DocumentCode
    1816562
  • Title

    CDF run IIb silicon vertex detector DAQ upgrade

  • Author

    Behari, Satyajit

  • Author_Institution
    Johns Hopkins Univ., Baltimore, MD, USA
  • Volume
    2
  • fYear
    2003
  • fDate
    19-25 Oct. 2003
  • Firstpage
    1143
  • Abstract
    The CDF particle detector operates in the beamline of the Tevatron proton-antiproton collider at Fermilab, Batavia, IL. The Tevatron is expected to undergo luminosity upgrades (Run IIb) in the future, resulting in a higher number of interactions per beam crossing. To operate in this dense radiation environment, an upgrade of CDF´s silicon vertex detector (SVX) subsystem and a corresponding upgrade of its VME-based DAQ system has been explored. Prototypes of all the Run Ilb SVX DAQ components have been constructed and tested successfully. In addition, a VME-based DAQ system has been developed as a fast and inexpensive tool for silicon detector and DAQ component testing in the production phase. In this paper we present an overview of the Run Ilb silicon DAQ upgrade, emphasizing the new features and improvements incorporated into the constituent VME boards, and discuss a PCI-based DAQ system developed to facilitate production tests.
  • Keywords
    data acquisition; nuclear electronics; position sensitive particle detectors; silicon radiation detectors; CDF run IIb silicon vertex detector DAQ upgrade; Fermilab; Tevatron proton-antiproton collider; Data acquisition; Electronic components; Optical buffering; Optical receivers; Optical transmitters; Particle beams; Production systems; Radiation detectors; Silicon; System testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2003 IEEE
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-8257-9
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2003.1351893
  • Filename
    1351893