Title :
The development and evaluation of solid-state detector arrays for high energy x-ray imaging
Author :
Li, Yulan ; Li, Yuanjing ; Wang, Shaofeng ; Li, Shuwei ; He, Huilin
Author_Institution :
Dept. of Eng. Phys., Tsinghua Univ., Beijing, China
Abstract :
Several detector modules which consist of linear CdWO4 crystal arrays optically coupled to photodiode arrays were developed for a high energy X-ray NDT system. An electron linear accelerator (LINAC) which produces pulsive X rays with maximum energy of 9 MeV is used for X ray source. 16 channels were assembled in each module, with crystal size of 0.8 mm × 5 mm × 30 mm and pitch size of 1.3 mm. Lead spacers were placed between crystals to reduce the cross-talk. Based on M-C simulation, the detection efficiency of the detector can reach 70%, energy deposit rate 30%, while crosstalk can be reduced to 5%. After fabrication, we tested their performances under the radiation sources of 60Co, 6 MeV LINAC and 9 MeV LINAC. The results show that the arrays satisfy the meet of the NDT system.
Keywords :
X-ray imaging; nondestructive testing; NDT system; detection efficiency; detector modules; high energy x-ray imaging; linear CdWO4 crystal arrays; photodiode arrays; solid-state detector arrays; Electron optics; Linear particle accelerator; Optical arrays; Optical coupling; Optical crosstalk; Sensor arrays; Solid state circuits; X-ray detection; X-ray detectors; X-ray imaging;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2003 IEEE
Print_ISBN :
0-7803-8257-9
DOI :
10.1109/NSSMIC.2003.1351949