  • Title

    Time characteristics of scintillations excited in xenon doped liquid krypton by relativistic particles

  • Author

    Akimov, D. ; Bolozdynya, A. ; Burenkov, A. ; Churakov, D. ; Osipova, T. ; Petshina, O. ; Safronov, G. ; Smirnov, G. ; Solovov, V.

  • Author_Institution
    Inst. of Theor. & Exp. Phys., Moscow, Russia
  • Volume
    1
  • fYear
    1996
  • fDate
    2-9 Nov 1996
  • Firstpage
    80
  • Abstract
    The shape of scintillation signals, exited in liquid krypton, liquid xenon and their liquid mixture of Kr+1.7%Xe by relativistic positrons, positive pions, protons and deuterons with moments of 0.35-2.1 GeV/c is measured at a secondary beam of the ITEP proton synchrotron. The data are compared with results of measurements of noble liquid scintillations excited with nuclear radiation and relativistic electrons,
  • Keywords
    electron detection; krypton; liquid mixtures; liquid scintillation detectors; meson detection; proton detection; xenon; Kr; Kr:Xe; Xe; Xe doped liquid Kr; deuterons; noble liquid scintillations; positive pions; protons; relativistic particles; relativistic positrons; scintillation signals; time characteristics; Electrons; Mesons; Nuclear measurements; Particle beam measurements; Particle beams; Positrons; Protons; Shape measurement; Synchrotrons; Xenon;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1996. Conference Record., 1996 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-3534-1
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1996.590910
  • Filename
    590910