DocumentCode :
1819294
Title :
Fuzzy model for evaluation insulation in large generator
Author :
Liang, Zhang ; Ouyang Benhong ; Naikui, Gao ; Hengkun, Xie
Author_Institution :
State Key Lab. of Electr. Insulation for Power Equipment, Xi´´an Jiaotong Univ., China
Volume :
1
fYear :
2003
fDate :
1-5 June 2003
Firstpage :
262
Abstract :
The process of aging is attributed to many uncertain factors, and it was difficult to confirm the quantitative relations between the nondestructive parameters of insulation and the breakdown voltage. In this paper, by using mathematical method of fuzzy analysis the parameters are selected according to the correlativity coefficient between nondestructive parameters and breakdown voltage. Then the membership functions are decided and by using the verdict matrix method, each weight between nondestructive parameters and breakdown voltage is given. Finally a fuzzy model is established by those parameters obtained to evaluate the aging status by nondestructive parameters.
Keywords :
ageing; dielectric losses; electric generators; fuzzy set theory; insulation; partial discharge measurement; aging; breakdown voltage; fuzzy model; generator; insulation; nondestructive parameters; verdict matrix method; Aging; Dielectric losses; Dielectrics and electrical insulation; Electric breakdown; Equations; Frequency; Laboratories; Partial discharges; Power generation; Statistics;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Properties and Applications of Dielectric Materials, 2003. Proceedings of the 7th International Conference on
ISSN :
1081-7735
Print_ISBN :
0-7803-7725-7
Type :
conf
DOI :
10.1109/ICPADM.2003.1218402
Filename :
1218402
Link To Document :
بازگشت